Minimum Order Quantity | 1 Piece |
Mounting Type | DIN Rail |
Output Type | Analog |
Brand | BECKHOFF |
Usage/Application | PLC |
Number of Inputs | 9 Digits |
Technical data | EL6731 |
---|---|
Technology | PROFIBUS master/slave terminal |
Cycle time | differing DP cycle times per slave are possible using the CDL concept |
Fieldbus | PROFIBUS DP (standard), PROFIBUS DP-V1 (Cl. 1+2: acyclic services, alarms), DP-V2, PROFIBUS MC (equidistant) |
Number of fieldbus channels | 1 |
Minimum Order Quantity | 1 Piece |
Output Type | Digital |
Mounting Type | DIN Rail |
Brand | BECKHOFF |
Usage/Application | PLC |
Number of Inputs | 9 Digits |
Special features:
Minimum Order Quantity | 1 Piece |
Output Type | Digital |
Mounting Type | DIN Rail |
Brand | BECHKOFF |
Usage/Application | PLC |
Number of Inputs | 9 Digits |
Minimum Order Quantity | 1 Piece |
Mounting Type | DIN Rail |
Brand | BECKHOFF |
Output Type | Digital |
Usage/Application | PLC |
Number of Inputs | 9 Digits |
Number of inputs | 2 |
Power supply | via the E-bus |
Technology | 2-, 3-wire (default setting: 3-wire) |
Distributed clocks | – |
Input filter limit frequency | typ. 1 kHz |
Sensor types | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g. potentiometer, 10 Ω…1/4 kΩ), KTY sensors (types see documentation) |
Connection method | 2- or 3-wire (default: 2-wire) |
Conversion time | approx. 85 ms default setting, 2…800 ms configurable |
Measuring current | < 0.5 mA (load-dependent) |
Temperature range | -200…+850 °C (Pt sensors); -60…+250 °C (Ni sensors) |
Resolution | 0.1 °C per digit |
Measurement error/ uncertainty | < ±0.5 °C for Pt sensors |
Electrical isolation | 500 V (E-bus/signal voltage) |
Current consumption power contacts | – |
Current consumption E-bus | typ. 190 mA |
Bit width in the process image | 2 x 32 bit RTD input |
Special features | integrated digital filter, limit value monitoring, variable connection technology |
Weight | approx. 60 g |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
Relative humidity | 95 %, no condensation |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. rating/installation pos. | IP20/variable |
Pluggable wiring | for all ESxxxx terminals |
Approvals/markings | CE, UL, ATEX, IECEx |
Ex marking | ATEX: II 3 G Ex nA IIC T4 Gc IECEx: Ex ec IIC T4 Gc |
Minimum Order Quantity | 1 Piece |
Output Type | Digital |
Mounting Type | DIN Rail |
Brand | beckhoff |
Usage/Application | PLC |
Number of Inputs | 9 Digits |
Technology | PROFIBUS master/slave terminal |
Cycle time | differing DP cycle times per slave are possible using the CDL concept |
Fieldbus | PROFIBUS DP (standard), PROFIBUS DP-V1 (Cl. 1+2: acyclic services, alarms), DP-V2, PROFIBUS MC (equidistant) |
Number of fieldbus channels | 1 |
Data transfer rates | 9.6 kbaud…12 Mbaud |
Interfaces | 1 x D-sub socket, 9-pin, galvanically decoupled |
Bus device | max. 125 slaves with up to 244 bytes input, output, parameter, configuration or diagnostic data per slave |
Hardware diagnostics | status LEDs |
Distributed clocks | yes |
Bit width in the process image | total max.: 1.4 kbyte input and 1.4 kbyte output data |
Current consumption power contacts | – |
Current consumption E-bus | typ. 200 mA |
Weight | approx. 70 g |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
Relative humidity | 95 %, no condensation |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. rating/installation pos. | IP20/variable |
Ex marking | ATEX: II 3 G Ex nA IIC T4 Gc IECEx: Ex ec IIC T4 Gc |
Approvals/markings | CE, UL, ATEX, IECEx |
Minimum Order Quantity | 1 Piece |
Output Type | Digital |
Mounting Type | DIN Rail |
Brand | beckhoff |
Usage/Application | PLC |
Number of Inputs | 9 Digits |
Technical data | EK1110 |
---|---|
Task within EtherCAT system | conversion of the E-bus signals to 100BASE-TX Ethernet for extension of the EtherCAT network |
Data transfer medium | Ethernet/EtherCAT cable (min. Cat.5), shielded |
Distance between stations | 100 m (100BASE-TX) |
Protocol | any EtherCAT protocol |
Delay | approx. 1 µs |
Data transfer rates | 100 Mbit/s |
Configuration | not required |
Bus interface | 1 x RJ45 |
Power supply | from E-bus |
Current consumption E-bus | typ. 130 mA |
Electrical isolation | 500 V (supply voltage/Ethernet) |
Weight | approx. 50 g |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Relative humidity | 95 %, no condensation |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
Protect. rating/installation pos. | IP20/variable |
Approvals/markings | CE, UL, ATEX, IECEx |
Ex marking | ATEX: II 3 G Ex nA IIC T4 Gc IECEx: Ex ec IIC T4 Gc |
Minimum Order Quantity | 1 Piece |
Output Type | Digital |
Mounting Type | DIN Rail |
Brand | BECKHOFF |
Usage/Application | PLC |
Number of Inputs | 9 Digits |